Copyright © 2015 NEXCOM International Co., Ltd. All Rights Reserved.
99
APPC 1240T/1245T/1540T/1740T/1940T User Manual
Appendix A: Power Consumption
aPPendIx a: Power ConsumPtIon
Power Consumption Management
Purpose
The purpose of the power consumption test is to verify the power dissipation
of the system and the load of the power supply.
Test Equipment
1. PROVA CM-07 AC/DC CLAMP METER
2. Burn-in test ver:6.0
Device Under Test
DUT: sys#1
Test Procedure
1. Power up the DUT, boot into Windows XP.
2. Enter standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run Burn-in test program and apply 100% full loading.
5. Before and after testing, test the system insulation.
+12V +24V +30V
Full-Loading Mode 1.99A 1.04A 0.86A
Total 23.88W 24.96W 25.9W
Standby Mode 0.1A 0.1A 0.1A
Total 1.2W 1.2W 1.2W
APPC 1940T
+12V +24V +30V
Full-Loading Mode 2.13A 1.09A 0.91A
Total 25.56W 26.16W 27.3W
Standby Mode 0.1A 0.1A 0.1A
Total 1.2W 1.2W 1.2W