Copyright © 2012 NEXCOM International Co., Ltd. All Rights Reserved.
112
APPC 1230T/1231T/1235T/1530T/1531T/1730T/1731T/1930T/1931T User Manual
Appendix D: Power Consumption
Appendix D: Power Consumption
Power Consumption Management
Purpose
The purpose of the power consumption test is to verify the power dissipation
of the system and the load of the power supply.
Test Equipment
1. PROVA CM-07 AC/DC CLAMP METER
2. Burn-in test ver:2.0
Device Under Test
DUT: sys#1/
Test Procedure
1. Power up DUT and then boot Windows 7.
2. Enter the standby mode (HDD power down).
3. Measure the power consumption and record it.
4. Run the Burn-in test program to apply 100% full loading.
5. Measure the power consumption and record it.
+12V +24V +30V
Full-Loading Mode 3.2A 1.65A 1.26A
Total 38.4W 39.6W 37.8W
Standby Mode 0.75A 0.41A 0.36A
Total 9W 9.84W 10.8W
APPC 1930T/1931T
+12V +24V +30V
Full-Loading Mode 4.2A 2A 1.63A
Total 50.4W 48W 48.9W
Standby Mode 0.74A 0.41A 0.34A
Total 8.88W 9.84W 10.2W
APPC 1730T/1731T